National Wildfire Coordinating Group

Hose – Collapsible, 3” X 25’

NFES Number: 
000621
Category: 
Water Handling
Updated: 
2018-03
Storage and Shelf Life Checks: 
None

Initial Inspection/Disposal Criteria

  1. Visually inspect for burns, cuts, and damaged fittings.
  2. Inspect gasket for cracks or damage, if any replace.
  3. Return to stock if hose is banded, clean, and in unused condition.
  4. Refurbish if item passes initial inspection.
  5. Dispose of hose if it fails initial inspection or fails Testing for Performance.

Refurbishing Procedures

A. Cleaning

  1. Remove excess dirt from hose.
  2. Clean with damp rag.
  3. Apply a rubber protectant to prevent drying and cracking.

B. Repair

  • Replace gasket if necessary.

C. Testing for Performance

      Service pressure test:

  1. Start pump.
  2. Test for 3 minutes at 50 PSI.
  3. Inspect hose for leaks.
  4. Shut down pump.
  5. Drain hose completely.

D. Repackaging

  1. Local cache option.
  2. Protect male coupling threads.

 

Page Last Modified / Reviewed: 
2023-08-18