Skip to main content

Point Fire (Idaho) – July 28, 1995

 

This Day in History is a brief summary of a powerful learning opportunity and is not intended to second guess or be judgmental of decisions and actions. Put yourself in the following situation as if you do not know the outcome. What are the conditions? What are you thinking? What are YOU doing?

Incident Summary:

On July 28, 1995, dry thunderstorms moved into southwestern Idaho and sparked dozens of wildfires. At 1829, a fire was reported about 16 miles southwest of Boise. BLM and Kuna Rural Fire District (RFD) resources were dispatched to the fire. As they arrived on scene, the fire was 60 to 65 acres, actively burning in mature sagebrush and dense cheatgrass with moderate rates of spread. West winds 4 to 6 mph fanned 3- to 5-foot flame lengths along the flanks. The IC (BLM) instructed the BLM engines to split up and directly attack the flanks with Kuna engines 620 and 622 following behind them. Kuna Command instructed the two Kuna engines to stay together and follow the BLM engines to compensate for less experienced firefighters occupying engine 620. By 2010, it is reported that engines on both flanks had met and the spread of the fire had been stopped at 120 acres.

At 2022, the National Weather Service issued a Red Flag warning for dry lightning and locally strong winds, predicting gusts of up to 50 mph from a thunderstorm moving toward the fire. Engines along the northern perimeter of the fire are alerted via BLM Dispatch on a BLM radio channel.

Kuna engines 620 and 622 continued to mop-up along the northern flank, passing multiple federal fire resources and ending at a fence on the southeast corner of the fireline where they were given instructions to turn around and work back around the perimeter. The two worked in tandem until Kuna 622 ran out of water. Kuna 620 took the lead and continued using its remaining water. Using the radio in a nearby BLM engine, Kuna 622 contacted the IC who instructed them refill and standby due to the predicted high winds.

While Kuna 622 was en route to refill, Kuna 620 contacted them with a report that their vehicle was overheating. They are instructed to clean the radiator screen. Soon after, and for unknown reasons, Kuna 620 turned north on a two-track road then north-northeast, driving cross-country through unburned heavy sagebrush. At this point, Kuna 620 became disabled.

At about 2046, the fire escaped the northern perimeter at several locations, fanned by strong south winds from the thunderstorm. Several fire personnel immediately drove north to assess fire behavior. They saw that the fire was burning intensely with flame lengths over 20 feet and an estimated rate of spread of 560 feet/minute. They see a stationary engine in the path of the oncoming flame front and made repeated attempts to contact the engine on the BLM tactical channel but received no response. They did not know whether the engine was occupied.

At 2049, Kuna 620 contacts the Kuna Commander on a local non-federal frequency and reported, “We are on the north line. We have fire coming hard, and this thing has died.” The Kuna 620 engine crew made another a radio transmission one minute later, “The truck’s been overtaken by fire!” That was their last transmission. Two firefighters lost their lives. It took 4 minutes from the point of escape for the fire to overrun the disabled engine.


Discussion Points:

L - How do you establish and maintain lookouts during initial attack?

  • If terrain is relatively flat, can we be lookouts for other crews nearby? If so, how?

C - The BLM IC could not monitor Kuna Command because the frequency was not programmed into his radio. Some Kuna crews could utilize the BLM frequencies while others could not. Kuna Command did not always have capability for radio communications with all units. And Kuna RFD Engines 620 and 622 had communication capabilities with both BLM and Kuna Command but could not communicate with Kuna Command once they switched to the BLM frequency.

  • During initial attack, how do you establish and maintain effective communications with other agencies and cooperators?
  • As an IC, how do you ensure Red Flag warnings and other vital information is received by all fire resources?
  • What will you and your crew do during any fire assignment to get accurate information about weather and current fire behavior?

E and S - Sometimes it is necessary to travel through the unburned fuel while accessing the fire, burning out, or shuttling water.

  • What are your concerns?
  • How do you maintain Escape Routes and Safety Zones:
    • As you move down the fireline?
    • When en route to refill?
  • How much water do you keep as reserve in the tank?

 

 

Last Modified / Reviewed:

Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee.


Follow NWCG on Twitter and Facebook

NWCG Latest Announcements

NWCG Equipment Technology Committee Releases Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention

Date: November 14, 2024
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention. Misaligned toolless fuel caps on Stihl chainsaws have led to recurring fuel spillage, fuel ignition, and burn injuries during wildland fire management operations.

This Safety Warning is intended to highlight the details and recommended procedures for the installation of a Stihl chainsaw toolless fuel cap, as well as how to identify and correct a misaligned, damaged, or broken fuel cap to help prevent fuel spillage.

References:

NWCG Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention

Advertencia de equipos 24-001: Prevención de derrames de la tapa de combustible sin herramientas de la motosierra Stihl

NWCG Alerts

The Incident Position Standards and Next Generation Position Task Book are now available for Equipment Time Recorder (EQTR)

Date: November 13, 2024
Contact: Incident Business Committee

NWCG is excited to announce that the NWCG Incident Position Standards for Equipment Time Recorder, PMS 350-51 and NWCG Position Task Book for Equipment Time Recorder (EQTR), PMS 311-51 are now available.

The Performance Support Package, which for EQTR, includes the Incident Position Standards and Next Generation Position Task Book were developed through the Incident Performance and Training Modernization (IPTM) effort. The Performance Support Package will support trainees, those qualified in the position, and evaluators.

References:

NWCG Equipment Time Recorder Position Page

NWCG Incident Position Standards for Equipment Time Recorder, PMS 350-51

NWCG Position Task Book for Equipment Time Recorder (EQTR), PMS 311-51

The Incident Position Standards and Next Generation Position Task Book are now available for Personnel Time Recorder (PTRC)

Date: November 13, 2024
Contact: Incident Business Committee

NWCG is excited to announce that the NWCG Incident Position Standards for Personnel Time Recorder, PMS 350-53 and NWCG Position Task Book for Personnel Time Recorder (PTRC), PMS 311-53 are now available.

The Performance Support Package, which for PTRC, includes the Incident Position Standards and Next Generation Position Task Book were developed through the Incident Performance and Training Modernization (IPTM) effort. The Performance Support Package will support trainees, those qualified in the position, and evaluators.

References:

NWCG Personnel Time Recorder Position Page

NWCG Incident Position Standards for Personnel Time Recorder, PMS 350-53

NWCG Position Task Book for Personnel Time Recorder (PTRC), PMS 311-53

NWCG Risk Management Committee Releases Safety Bulletin: 24-001 Use of Respirators on Wildland Fires

Date: November 7, 2024
Contact: Risk Management Committee

The Risk Management Committee (RMC) has released Safety Bulletin: 24-001 Use of Respirators on Wildland Fires. As wildland fire respirators are available through several established vendors, wildland fire personnel need to understand regulations and limitations of respirator use in the workplace.

Safety Bulletin 24-001 outlines the following topics regarding respirator use for wildland fires:

  • Requirements for Respirator Use
  • Voluntary Respirator Use
  • Current Respirator Options
  • Unknown Risks of Respirator Use

This bulletin also provides mitigation recommendations to help reduce smoke exposure for wildland firefighting efforts.

References:

NWCG Safety Bulletin: 24-001 Use of Respirators on Wildland Fires

NWCG Smoke Management Guide for Prescribed Fire, PMS 420-3

VIDEO: Protecting Wildfire Personnel from Smoke - How Incident Management Teams Address Smokes Risks

VIDEO: Smoke, Knowing the Risks