Initial Inspection/Disposal Criteria

  1. Inspect for cuts, tears, frayed, or burned areas on webbing and harness material. Inspect for any area of abrasion that has weakened the webbing beyond repair. Inspect all plastic hardware for proper function, cracks, breaks, or missing components.
  2. Return to stock if item shown no sign of use or damage.
  3. Refurbish if holes, cuts, tears or burns are easily repaired, broken or missing components are replaceable, and if repairs are economically feasible.
  4. Dispose of item if excessive wear or damage is found and it is not economically feasible to return item to a like new condition.

Refurbishing Procedures

A. Cleaning - CLASS 2 CORDURA (MACHINE WASH OK)

  1. Allow any mud or loose dirt to dry, and remove using a stiff-bristle brush. If stains remain, wash as recommended below.
  2. Remove light oil and dirt stains by brushing with a solution of warm water and a mild detergent, rinse thoroughly, and hang to dry. “Mild detergents” includes most home laundry detergents that contain no chlorine bleach or added scents.
  3. For heavier oil or grease, soak in water-soluble biodegradable degreaser for at least 30 minutes, brush with a bristle brush, rinse thoroughly, and hang to dry.
  4. If machine washing, use only cold water on a gentle cycle and air dry.
  5. Where no other method is cleaning the fabric, wash with pressure washer set at wide fan, warm water, and only allow nozzle close enough as necessary for cleaning, the further away the better for the fabric. DO NOT MACHINE DRY. DO NOT USE BLEACH.

B. Repair

  1. Repair holes, cuts, tears, and/or burns; if economically feasible.
  2. Replace damaged hardware.

C. Testing for performance

  • Test hardware by fastening and unfastening. The hardware should function easily with little applied force and without difficulty in opening and closing.

D. Repackaging

  • Local cache option.

 

NWCG Latest Announcements

NWCG Training Catalog now on Wildland Fire Learning Portal

Date: April 25, 2023
Contact: NWCG Training  

The National Wildfire Coordinating Group (NWCG) has migrated the training catalog from the NWCG website to the Wildland Fire Learning Portal (WFLP) as part of our ongoing efforts to streamline processes and improve efficiency. To facilitate this transition, the training catalog remains available on www.nwcg.gov through April 2024.

Starting May 2024, the training catalog will no longer be accessible on www.nwcg.gov. However, you can still access the complete training catalog by logging in as a guest to the WFLP.

References:

Wildland Fire Learning Portal

 

NWCG Website Migration

Date: April 01, 2024
Contact: NWCG Webmaster

The National Wildfire Coordinating Group is thrilled to announce a significant upgrade to https://www.nwcg.gov, involving a comprehensive redesign of over 7,000 web pages. This enhancement is focused on improving user experience. The migration to the new NWCG website will commence on April 2, 2024, starting at noon EST and is expected to take a few hours. 

During the migration period, as the www.nwcg.gov domain-name-location updates across the Internet, you might encounter either the current or the new site depending on your location. We request your patience during this transition. If you are not redirected to the new site by April 3, 2024, we recommend clearing your browser’s cache and refreshing the page.

Please note that while navigating the revamped website, there may be instances of broken links or errors. Our dedicated web migration team has made significant efforts to minimize such issues prior to launch and will promptly address any that arise via use of analytic reports. We value your patience and understanding as we work towards enhancing your overall website experience.

WFSTAR 2023 Year in Review and 2024 Core Component Module Packages Available

Date: March 6, 2024
Contact: Joe Schindel 

The 2023 Fire Year in Review module and 2024 Core Component Module Packages for RT-130, Wildland Fire Safety Training Annual Refresher (WFSTAR) are now available on the NWCG website. The 2024 Core Component Module Package provides all content needed to deliver RT-130.

 

References:

WFSTAR 2023 Fire Year in Review module

WFSTAR 2024 Core Component Module Packages

2024 NWCG Executive Board Annual Letter

Date: March 6, 2024
Contact: NWCG

The NWCG Executive Board is privileged to share with you the 2024 NWCG Executive Board Annual Letter. As we look into the future and navigate an incredibly complex and dynamic environment, we must remain focused on our mission while actively engaging in national conversations regarding numerous wildland fire initiatives. In 2024, we prioritize building upon our successes and committing to continuous improvement. Key priorities and considerations for this year include: 

  • Determining Core Workload
  • Ensuring Incident Performance and Training Modernization (IPTM) Success
  • Improving Efficiencies
  • Firefighter Health and Wellness
  • Engagement in National Conversations

Together we will continue to make significant strides in the challenging and vital work that lies ahead. 

 

References:

2024 NWCG Executive Board Annual Letter