Valve – Wye, Gated, Zinc, 3/4” NH-F X 3/4” NF-M X 3/4” NH-M

NFES #:
000272
Category:
Water Handling
Updated:
Storage and Shelf Life Checks:
None

This item has been deleted from the NFES catalog.  

National Caches are not stocking or refurbishing this item.

Initial Inspection/Disposal Criteria

  1. Inspect for the following:
    1. Handles-bent, broken, missing, too tight, too loose, expansion pins coming out or missing, handles correct (left and right) and positioned properly.
    2. Male flange-flange missing, lock-ring and set-screws functional, damaged threads, smooth flat surface on flange, burrs on threads, or loose male flange.
    3. Female coupling-Coupling spins freely, gasket present and in good condition free of cracks or damage, burrs on threads.
    4. Casting (body)-Fire damage—look for further damage, O-rings in good condition, corrosion, cracks, and burrs.
    5. Plastic sphere-Inspect sphere while turning handle; if pitted or rough, replace.
  2. Return to stock if item is clean, passes inspection and is in unused condition.
  3. Refurbish if deficiencies are discovered during the inspection process and item requires cleaning.
  4. Dispose of item if damages are not repairable or item has sustained damage caused by fire.

Refurbishing Procedures

A. Cleaning

  1. Clean in a mild detergent with brush and scouring pad or use parts washer or high pressure wash to remove foreign matter such as mud, dirt or grease. Rinse thoroughly.
  2. Do not soak for extended periods of time as detergent will corrode the metal.
  3. Stand upright with barrels in open position to drain water and dry.
  4. Lubricate with appropriate type of lubricant.

B. Repair

  1. Replace missing or damaged O-rings and gaskets.
  2. Replace broken, missing handles.
  3. Repair or replace male flange if damaged is discovered on face or threads.
  4. Replace female coupling or bearings if not spinning freely.

C. Testing for Performance

  1. Install valve on test pump.
  2. Turn on water to pump and open valve to expel air then close valve.
  3. Turn on pump
  4. NFES #000259 and NFES #000231 test at 300 PSI for 3 minutes.
  5. NFES #000904 and NFES #000272 test at 100 PSI for 3 minutes.
  6. Inspect for leaks around the gasket, at the handles, and around flanges while on test pump.
  7. If valve leaks, repair as necessary or dispose of through local procedures.
  8. Retest after repairs are made.

D. Repackaging

  1. Ensure item is completely dry prior to packaging.
  2. Packaging: 
    • Use NFES #000823 carton (15” x 15” x 10”) for the following: NFES #000231, #000259 standard pack of 10 EA per carton. 
    • Use NFES #008064 carton (10” x 8” x 6”) for the following: NFES #000904 standard pack of 50 EA per carton. 
    • Use NFES #008076 carton (8” x 4” x 4”) for the following: NFES #000272 standard pack of 10 EA per carton.

 

NWCG Latest Announcements

Updated NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

Date: May 10, 2024
Contact: IFUASS Qualification and Curriculum Board (IFUASS) 

The 2024 revision of the NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515 is now available. PMS 515 standardizes the processes and procedures for interagency use of Unmanned Aircraft Systems (UAS), including pilot inspections and approvals. This publication is now available as a PDF for easy use offline.

References:

NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

Memorandum 24-003: Removal of Type 1 Command and General Staff (C&G) Incident Position Qualification Pathways

Date: May 10, 2024
Contact: Aitor Bidaburu 

The purpose of this memorandum is to provide NWCG direction for removal of the Type 1 Command and General Staff (C&G) incident position qualification pathways to transition to Complex Incident Management (CIM). Responders may continue to utilize available NWCG pathways to attain Type 1 C&G qualifications until December 31, 2024.

References:

Memorandum 24-003

CIM Story Map

2024 Professional Reading Program

Date: April 26, 2024
Contact: Wildland Fire Leadership Development Program (WFLDP) 

The Wildland Fire Leadership Development Program is announcing the 2024 Professional Reading list! The intent of the Professional Reading Program is to promote the reading and discussion of these books throughout the year. Discussion guides are provided and the corresponding Wildland Fire Leadership Levels have been identified.

The five books chosen for this year are: Young Men and Fire by Norman Maclean, The Wisdom of the Bullfrog by William H. McRaven, The Art of Clear Thinking by Hasard Lee, Emotional Agility by Susan David, and Writing to Persuade by Trish Hall.

References:

Professional Reading Program

Wildland Fire Leadership Levels

NWCG Training Catalog now on Wildland Fire Learning Portal

Date: April 25, 2023
Contact: NWCG Training  

The National Wildfire Coordinating Group (NWCG) has migrated the training catalog from the NWCG website to the Wildland Fire Learning Portal (WFLP) as part of our ongoing efforts to streamline processes and improve efficiency. To facilitate this transition, the training catalog remains available on www.nwcg.gov through April 2024.

Starting May 2024, the training catalog will no longer be accessible on www.nwcg.gov. However, you can still access the complete training catalog by logging in as a guest to the WFLP.

References:

Wildland Fire Learning Portal