Skip to main content

PMS 448

Flight Suit – Chest Size 44, Inseam 32 1/2” (L)

NFES #
000545
Category
Clothing
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Inspect for holes, cuts, tears, burns, or torn seams. Inspect hook and pile fastener missing or that does not provide adequate closure, repair or dispose of. Inspect for broken zippers or missing a sliders. Open and close the hook and pile fasteners to ensure they provide an adequate and secure closure. Open and close zipper to ensure smooth operations and secure closures.
  2. Return to stock if item is clean and all components are in good working condition
  3. Refurbish if cleaning is the only refurbishment required.
  4. Dispose of item if any damage is found in the inspection process.

Refurbishing Procedures

A. Cleaning

  1. Follow the cleaning procedures described in the publication, Nomex®- Aramid Fiber -Laundering Guide (H71603).
    Additional information can be obtained by calling DuPont at 1–800–453–8527 or by writing:
    DuPont Advanced Fibers Systems
    Chestnut Run Plaza
    Laurel Run Building
    Wilmington, DE 19880-0705
  2. Abbreviated washing procedures from above publication:
    1. “Garments of NOMEX® should be washed separately from other articles to avoid contamination with lint of flammable fibers.”
    2. “Tests show that formulations designed for use at a temperature of 140 °F (60 °C) or less – such as high-surfactant, low-alkalinity products – adequately clean NOMEX® and provide the best fabric color retention.”
    3. “For heavily stained and oily garments of NOMEX®, a higher temperature wash formula may be required for adequate cleaning.”
    4. “Garments made of NOMEX® must be adequately rinsed to remove residual wash chemicals.”
    5. “In some instances, tumble dry conditioning is the only finishing necessary for garments of NOMEX®.”
    6. “…dry cleaning is an alternative method of removing heavy soil and may be preferable to repeated high-temperature washing.”
  3. If items are taken to vendor laundry facilities for refurbishment; ensure that they receive a copy of this refurbishment standard. The laundry facility must satisfy both – the requirements as set by the manufacturer specification and the agreement made with the local agency.

B. Repairs

  • None

C. Test for performance

  • None

D. Repackaging

  • Local cache option

 

NWCG Latest Announcements

NWCG Welcomes the Incident Management Team Association as an Associate Member

Date: May 21, 2025
Questions?  Please contact:
https://www.nwcg.gov/contact-us

The NWCG Executive Board is honored to announce that the Incident Management Teams Association (IMTA) has joined the National Wildfire Coordinating Group as an associate member.

IMTA is a dedicated group of incident management professionals committed to enhancing the profession by promoting standards and fostering collaboration across federal, state, local, Tribal, and private sector partners throughout all phases of incident management.

“Joining NWCG aligns with our mission to elevate incident management professionals nationwide,” said Dr. Randal Collins, President of IMTA. “This is a proud moment for all of us committed to advancing public safety.”

References:

Incident Management Teams Association

National Wildfire Coordinating Group

Updated NWCG Guide for Wildland Fire Modules, PMS 431

Date: May 14, 2025
Questions?  Please contact:
Fire Use Subcommittee

The updated NWCG Guide for Wildland Fire Modules, PMS 431 serves as a supplemental resource for wildland fire module operations, providing information frequently used in the field.

PMS 431 defines the organizational structure, staffing, and qualifications for Type 1 and Type 2 Wildland Fire Modules, outlining their roles in wildland fire suppression, prescribed fire, and resource management. The NWCG Guide for Wildland Fire Modules, PMS 431, should be used in conjunction with the NWCG Standards for Wildland Fire Module Operations, PMS 430.

References:

NWCG Guide for Wildland Fire Modules, PMS 431

NWCG Standards for Wildland Fire Module Operations, PMS 430

Updated NWCG Standards for Wildland Fire Resource Typing, PMS 200 Now Includes Off-Highway Vehicle Typing Standards

Date: May 13, 2025
Questions?  Please contact:
Mobile Fire Equipment Subcommittee 

The NWCG Standards for Wildland Fire Resource Typing, PMS 200 has been updated to include newly developed Off-Highway Vehicle (OHV) typing standards. These standards organize OHV information into logical categories and outline key safety requirements for occupants.

NWCG Standards for Wildland Fire Resource Typing, PMS 200 establishes minimum typing standards for aircraft, crews, and equipment used in national mobilization to wildland fire incidents. Typing designations are assigned based on measurable capability and performance criteria.

References:

NWCG Standards for Wildland Fire Resource Typing, PMS 200

NEW! S-204, Interpersonal and Critical Thinking Skills for Safety Officers Now Available

Date: May 12, 2025
Questions?  Please contact:
Risk Management Committee

The S-204, Interpersonal and Critical Thinking Skills for Safety Officers self-directed online course is now available! Developed through the Incident Performance and Training Modernization (IPTM) effort, this training supports individuals working towards Safety Officer, Field (SOFF) incident qualifications.

S-204, Interpersonal and Critical Thinking Skills for Safety Officers focuses on facilitating hazard mitigation conversations and building trust to influence safety-related decisions. Individuals can self-enroll through the Wildland Fire Learning Portal (WFLP).

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

S-204, Interpersonal and Critical Thinking Skills for Safety Officers 

NWCG Safety Officer, Field (SOFF) Position Page

Wildland Fire Learning Portal