Skip to main content

Stand 2 - Baca Ranch Boundary

Submitted by Anonymous (not verified) on

The Baca Ranch (currently referred to as the Valles Caldera Trust) is located northwest of Cerro Grande Peak with the boundary located in the saddle west of the peak. This first stand is accessed from the parking area by hiking directly up Frijoles Canyon.

After working a regular workday in preparation of the Upper Frijoles Prescribed Burn implementation, Upper Frijoles prescribed fire personnel including a 10-person Type II crew and 10 NPS employees hiked approximately 2½ hours up Cerro Grande Peak to attend a second operational briefing from the Burn Boss at 1900 on May 4, 2000. At 1920, a test fire is ignited near the summit of Cerro Grande Peak. The test fire is successfully completed and the fire behavior is within parameters. The go-decision is made to continue the prescribed fire by the Burn Boss.

Crews began blacklining by burning down the northeast edge of the fire from the test fire area. The holding crew will use backpack pumps, spruce bows, and changes in fuels and terrain to limit fire spread during blackline operations. Progress was slow using the ignition pattern outlined in the plan. The ignition pattern was changed to speed up the progress and the decision made by the burn boss to stop suppressing the fire on the interior side of the ignition lines.

Photo taken in September 2003 from the west side of Cerro Grande Peak, looking northwest towards Baca Ranch (Valles Caldera).

Photo was taken in September 2003 from the west side of Cerro Grande Peak, looking northwest towards Baca Ranch (Valles Caldera).

Photo taken in September 2003 from the saddle that borders Baca Ranch (Valles Caldera), looking towards Cerro Grande Peak. The fuels consist of primarily clump grass with light brush.

Photo was taken in September 2003 from the saddle that borders Baca Ranch (Valles Caldera), looking towards Cerro Grande Peak. The fuels consist of primarily clump grass with light brush.

 
Location (SRS)
POINT (-106.4175 35.8645333)

NWCG Latest Announcements

2025 Paul Gleason Award Winners Announced

Date:  August 13, 2026
Questions? 
Please contact: Leadership Development Subcommittee

The NWCG Qualifications Management Committee (QMC) and Leadership Development Subcommittee (LDSC) are proud to announce the recipients of the 2025 Paul Gleason "Lead By Example" awards. Award categories include Initiative and Innovation, Mentoring and Teamwork, and Motivation and Vision.

Congratulations to the awardees:

  • Hunter Bell, U.S. Forest Service — Initiative and Innovation
  • Shannon Deane, U.S. Wildland Fire Service— Initiative and Innovation
  • Chris Delaney, U.S. Wildland Fire Service — Motivation and Vision
  • Sean Peterson, U.S. Forest Service — Mentoring and Teamwork

References:

Paul Gleason Lead By Example Award

Wildland Fire Leadership Development Program (WFLDP)

Leadership Development Subcommittee

LMC Equipment Bulletin 26-001: Aquatic Invasive Species – Seasonal Reminder for Mussels

Date:  July 30, 2026
Questions? 
Please contact: Equipment and Technology Subcommittee

The Logistics and Equipment Management Committee (LMC) issued Equipment Bulletin 26-001: Aquatic Invasive Species - Seasonal Reminder for Mussels, reminding the wildland fire community that aquatic mussels continue to be a problem. Mussels rapidly colonize hard and soft surfaces, including aquatic plants and fire equipment, clogging pipes, fouling motors, disrupting water systems, and impacting native species.

To help prevent their spread, fire personnel must follow the decontamination procedures outlined in the NWCG Guide to Preventing Aquatic Invasive Species Transport by Wildland Fire Operations, PMS 444. Additionally, report any sightings immediately to your Lead Resource Advisor and include clear, close-up photos (with a pen or your hand for size reference) and location details.”

Read the complete LMC Equipment Bulletin 26-001, to learn more. 

References:

NWCG Alerts

LMC Equipment Bulletin 26-001: Aquatic Invasive Species - Seasonal Reminder for Mussels

NWCG Guide to Preventing Aquatic Invasive Species Transport by Wildland Fire Operations, PMS 444

Intermediate Faller (FAL2) Position Task Book Update

Date:  July 24, 2026
Questions? 
Please contact: Tree Felling Subcommittee

NWCG Operations Management Committee (OMC) has issued an update to the NWCG Position Task Book for Intermediate Faller (FAL2), PMS 311-91. To ensure clarity for both trainees and evaluators, the updated FAL2 Position Task Book (PTB) explicitly states who is authorized to sign off on your tasks:

“Evaluators must be qualified as a FAL2, or an Advanced Faller (FAL1).”

If you are currently working out of a previously published version of the FAL2 PTB, you do not need to restart. However, OMC highly encourages you to take the following step to prevent any confusion in the field:

  • Print and replace the updated evaluator information page (page 2) in your current physical PTB.

References:

Intermediate Faller (FAL2) Position Page

RMC Memo 26-01: Transition Plan for Implementing Updates to Intermediate Faller (FAL2) Position Qualifications

NWCG Position Task Book for Intermediate Faller (FAL2), PMS 311-91

Equipment Advisory 26-001: Potential Front Driveline Joint Failure on 2018 and Earlier Ram Pickups

Date:  July 10, 2026
Questions? 
Please contact: Equipment and Technology Subcommittee

The Logistics/Equipment Management Committee (LMC) has released Equipment Advisory 26-001: Potential Front Driveline Joint Failure on 2018 and Earlier Ram Pickups. This advisory highlights multiple U.S. Forest Service regions reporting front driveline joint failure incidents.

This advisory recommends firefighters and fire managers to: 

  • Follow all Ram-issued inspection, maintenance, and service guidance for front driveline joints. 
  • Consider installing a driveline loop. 
  • Coordinate with fleet managers and service providers to determine the most appropriate driveline loop kit for each pickup.

For further details, please refer to the complete advisory.

References:

Equipment Advisory 26-001: Potential Front Driveline Joint Failure on 2018 and Earlier Ram Pickups

Technical Service Bulletin: 03-002-21