Skip to main content

PMS 448

Shirt – Fire, Large, Long

NFES #
002078
Category
Clothing
Updated
Storage and Shelf Life Checks
None

Initial inspection/Disposal Criteria

  1. Inspect for holes, cuts, tears, or torn seams. Inspect for color change (yellow to white/pink) caused by exposure to heat. Dye sublimation is the result of heat baking the dye out of the fabric. Areas of fabric with dye sublimation do not affect the performance of the shirt. Charring (hard brittle fabric that will then form a hole) in association with sublimation will decrease the performance of the fabric and the item should be disposed of. Inspect for loose or missing buttons, burn marks, stains and any sign of exposure to poison ivy/oak/sumac.
  2. Return to stock if item is clean and in unused condition.
  3. Refurbish any missing buttons, holes or seams. Launder each item following cleaning instructions.
  4. Dispose of item when repairs are not economically feasible or would make item unsafe for use.

Refurbishing Procedures

A. Cleaning – DO NOT USE BLEACH TO CLEAN FABRIC.

  1. Follow the cleaning procedures described in the publication, Nomex®- Aramid Fiber -Laundering Guide (H71603).
    Additional information can be obtained by calling DuPont at 1–800–453–8527 or by writing:
    DuPont Advanced Fibers Systems
    Chestnut Run Plaza Laurel Run Building
    Wilmington, DE 19880-0705
  2. Abbreviated washing procedures from above publication:
    1. “Garments of NOMEX® should be washed separately from other articles to avoid contamination with lint of flammable fibers.”
    2. “Tests show that formulations designed for use at a temperature of 140 °F (60 °C) or less – such as high-surfactant, low-alkalinity products - adequately clean NOMEX® and provide the best fabric color retention.”
    3. “For heavily stained and oily garments of NOMEX®, a higher temperature wash formula may be required for adequate cleaning.”
    4. “Garments made of NOMEX® must be adequately rinsed to remove residual wash chemicals.”
    5. “In some instances, tumble dry conditioning is the only finishing necessary for garments of NOMEX®.”
    6. “…dry cleaning is an alternative method of removing heavy soil and may be preferable to repeated high-temperature washing.”
  3. If items are taken to vendor laundry facilities for refurbishment; ensure that they receive a copy of this refurbishment standard. The laundry facility must satisfy both--the requirements as set by the manufacturer specification and the agreement made with the local agency. 

Nomex® Clothing Exposed to Poison Oak/Ivy/Sumac

RESEARCH

At the request of the National Support Cache Refurbishing Standards Committee, MTDC researched the practicality of laundering Nomex firefighting clothing that has been contaminated with urushiol oil (the allergen to which the body reacts) from poison oak/ivy/sumac exposure. Current cache practices range from normal washing procedures to disposal of shirts and pants that have known urushiol contamination.

A search of on-line sources didn’t produce any special care instructions beyond normal laundering. Some examples:

  • “All clothing should be laundered, and everything else that may be contaminated with urushiol should be washed thoroughly.” American Academy of Dermatology. 
  • “…be sure to wash your clothing promptly with detergent…” Mayo Clinic. 
  • “Washing clothes with ordinary laundry soap will remove urushiol.” Missouri Department of Conservation.

A phone conversation with Daniel Boelman, RN, BSN, Customer Service Manager with Zanfel Laboratories, Inc. also indicated no special treatment beyond normal laundering. (Zanfel produces a commercially available poison oak/ivy cream). Mr. Boelman recommended using vinyl gloves when handling contaminated clothing.

On 11/17/2008 the Forest Service filed a SAFENET Supplemental Corrective Action concerning poison oak reactions experienced by firefighters during the 2008 fire season in California. In that posting, it is recommended that “All clothing and equipment should be laundered immediately …A degreaser was recommended for helping to remove urushiol from clothing and equipment.”

RECOMMENDATION

MTDC recommends that fire clothing contaminated with urushiol oil be cleaned following normal Nomex laundering procedures. Extra care should be exercised when handling the contaminated clothing. Clearly labeled plastic bags should be used to separate contaminated clothing from other returned clothing. Commercial laundry personnel should wear long sleeves and vinyl gloves when handling contaminated clothing and dispose of any bags used for transporting the clothes to the laundering facility. As an extra precaution, supply cache and laundry workers could apply an over-the-counter skin-barrier product that contains bentoquatum (such as Ivy Block or Stokoguard) before handling contaminated clothing. Bentoquatum helps prevent urushiol from penetrating the skin. After exposure, workers’ clothes should be washed and gloves disposed of. 

B. Repairs

  1. Repair holes, cuts, tears, burns, and torn seams by darning, patching, or by duplicating the original construction.
  2. Use Nomex® (Aramid) patching material for all repairs.
  3. Re-stitch frayed buttonholes using a buttonhole or zigzag stitch that has 50 to 60 stitches per buttonhole.
  4. Replace damaged hook and pile fastener tape with tape of the same length, width, and quality as the original.

C. Testing for Performance

  1. Inspect items after laundering to ensure all foreign matter and stains have been removed. If items fail second inspection spot treat problem areas or remove item from service.
  2. Test all replacement hook and pile fasteners after repair. 

D. Repackaging 

  • 30 each of same NFES #/size in NFES#002007 carton (24”X16”X16”).

 

NWCG Latest Announcements

NWCG Welcomes the Incident Management Team Association as an Associate Member

Date: May 21, 2025
Questions?  Please contact:
https://www.nwcg.gov/contact-us

The NWCG Executive Board is honored to announce that the Incident Management Teams Association (IMTA) has joined the National Wildfire Coordinating Group as an associate member.

IMTA is a dedicated group of incident management professionals committed to enhancing the profession by promoting standards and fostering collaboration across federal, state, local, Tribal, and private sector partners throughout all phases of incident management.

“Joining NWCG aligns with our mission to elevate incident management professionals nationwide,” said Dr. Randal Collins, President of IMTA. “This is a proud moment for all of us committed to advancing public safety.”

References:

Incident Management Teams Association

National Wildfire Coordinating Group

Updated NWCG Guide for Wildland Fire Modules, PMS 431

Date: May 14, 2025
Questions?  Please contact:
Fire Use Subcommittee

The updated NWCG Guide for Wildland Fire Modules, PMS 431 serves as a supplemental resource for wildland fire module operations, providing information frequently used in the field.

PMS 431 defines the organizational structure, staffing, and qualifications for Type 1 and Type 2 Wildland Fire Modules, outlining their roles in wildland fire suppression, prescribed fire, and resource management. The NWCG Guide for Wildland Fire Modules, PMS 431, should be used in conjunction with the NWCG Standards for Wildland Fire Module Operations, PMS 430.

References:

NWCG Guide for Wildland Fire Modules, PMS 431

NWCG Standards for Wildland Fire Module Operations, PMS 430

Updated NWCG Standards for Wildland Fire Resource Typing, PMS 200 Now Includes Off-Highway Vehicle Typing Standards

Date: May 13, 2025
Questions?  Please contact:
Mobile Fire Equipment Subcommittee 

The NWCG Standards for Wildland Fire Resource Typing, PMS 200 has been updated to include newly developed Off-Highway Vehicle (OHV) typing standards. These standards organize OHV information into logical categories and outline key safety requirements for occupants.

NWCG Standards for Wildland Fire Resource Typing, PMS 200 establishes minimum typing standards for aircraft, crews, and equipment used in national mobilization to wildland fire incidents. Typing designations are assigned based on measurable capability and performance criteria.

References:

NWCG Standards for Wildland Fire Resource Typing, PMS 200

NEW! S-204, Interpersonal and Critical Thinking Skills for Safety Officers Now Available

Date: May 12, 2025
Questions?  Please contact:
Risk Management Committee

The S-204, Interpersonal and Critical Thinking Skills for Safety Officers self-directed online course is now available! Developed through the Incident Performance and Training Modernization (IPTM) effort, this training supports individuals working towards Safety Officer, Field (SOFF) incident qualifications.

S-204, Interpersonal and Critical Thinking Skills for Safety Officers focuses on facilitating hazard mitigation conversations and building trust to influence safety-related decisions. Individuals can self-enroll through the Wildland Fire Learning Portal (WFLP).

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

S-204, Interpersonal and Critical Thinking Skills for Safety Officers 

NWCG Safety Officer, Field (SOFF) Position Page

Wildland Fire Learning Portal