Skip to main content

Pump – Trombone, Backpack, Single Action

NFES #
000151
Category
Water Handling
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Inspect for obvious damage. 
  2. Inspect for burns and cracks. Dispose of if these are found.
  3. Inspect for damaged threads. If beyond repair dispose of. Ensure tip is secured to wand with a 3-4 inch length of ball chain.
  4. Place hose in water and pump handle to validate that pump works properly.
  5. Return item to stock if it shows no sign of use or damage.
  6. Dispose of item if unable to repair.

Refurbishing Procedures

A. Cleaning

  1. Wash and clean all items of foreign matter, such as mud, dirt, and grease.
  2. Clean in mild detergent with brush or scouring pad as needed.
  3. Rinse thoroughly.

B. Repair

  1. If pump pressure is not sufficient, remove pump unit and replace O-rings.
  2. If suction hose is kinked, replace hose.
  3. Ensure quick connection on pump has proper seating.
  4. Check hose connection to pump for tightness; if loose, use a hose clamp.
  5. Replace length of ball chain between wand and removable tip if missing.
  6. Check supply hose on pump assembly for obstructions and tight connections, bent push rods, and clogged tips.
  7. Check spring and ball bearing.
  8. Lubricate slide with appropriate lubricant, e.g., Chevron NLGI2 or equivalent.

C.  Tests for Performance

  • Place end of hose in water and pump trombone. Ensure that it fills and discharges water properly without back feeding water out of the suction hose.

D.  Repackaging

  1. Suggested packaging of NFES #000151, 10 each in NFES #000385 carton (7.25” x 9.25” x 26”) or 25 each in NFES #002006 carton (23” x 19” x 10”).
  2. Ensure suction hose is not kinked when packaging.

 

NWCG Latest Announcements

Incident Position Standards and Next Generation Position Task Book Available for Firing Boss, Single Resource

Date: April 30, 2025
Questions?  Please contact:
Fuels Management Committee

NWCG is excited to announce that the NWCG Incident Position Standards for Firing Boss, Single Resource, PMS 350-105, and the NWCG Position Task Book for Firing Boss, Single Resource (FIRB), PMS 311-105, are now available. 

These resources, part of the Performance Support Package developed through the Incident Performance and Training Modernization (IPTM) effort, support trainees, qualified personnel, and evaluators. 

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

 

References:

NWCG Firing Boss, Single Resource Position Page

NWCG Incident Position Standards for Firing Boss, Single Resource, PMS 350-105

NWCG Position Task Book for Firing Boss, Single Resource (FIRB), PMS 311-105

Incident Position Standards and Next Generation Position Task Book Available for Helicopter Crewmember

Date: April 28, 2025
Questions?  Please contact:
Interagency Helicopter Operations Subcommittee

NWCG is excited to announce that the NWCG Incident Position Standards for Helicopter Crewmember, PMS 350-22, and the NWCG Position Task Book for Helicopter Crewmember (HECM), PMS 311-22, are now available.

These resources, part of the Performance Support Package developed through the Incident Performance and Training Modernization (IPTM) effort, support trainees, qualified personnel, and evaluators.

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

NWCG Incident Position Standards for Helicopter Crewmember, PMS 350-22

NWCG Incident Position Standards for Helicopter Crewmember, PMS 350-22

NWCG Position Task Book for Helicopter Crewmember (HECM), PMS 311-22

Updated NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

Date: April 23, 2025
Questions?  Please contact:
Interagency Fire Unmanned Aircraft Systems Subcommittee

The NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515 standardizes processes and procedures for the interagency use of Unmanned Aircraft Systems (UAS), including pilot inspections and approvals. This updated publication provides the aviation community with standards to ensure UAS are used safely, effectively, and efficiently in support of fire management goals and objectives.

References:

NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

NWCG National Interagency Aviation Committee

ETC Bulletin 25-001: Retrofitted Hot/Cold Beverage Kits - 2025 Field Season

Date: April 16, 2025
Questions?  Please contact:
Equipment Technology Committee

Due to spout failures and the associated risk of burn injuries, manufacturers have retrofitted the Hot/Cold Beverage Kits using a heat-shrinking band to secure the black spout at the insertion site. The updated kits feature a fluorescent label on each full kit assembly for easy identification. Catering units are encouraged to confirm the clear heat-shrinking bands are intact around each spout before filling.

ETC Bulletin 24-001 regarding Hot/Cold Beverage Kits has been archived and replaced by ETC Bulletin 25-001 for the 2025 season.

References:

NWCG Alerts

ETC-EB-25-001 Retrofitted Hot/Cold Beverage Kits