First, a Fire Behavior 101 refresher:  You can warm yourself around the sides of a campfire for quite some time; that’s radiant heat.  If you hold your hands over the top of the fire, you’ll get burned relatively quickly; that’s convective heat.

Basically, wind or slope can tip the flames over, so that the convective heat is no longer going straight up, but is now aimed more along the ground, sending the heat and hot gasses much further ahead.  This causes pre heating of the fuels, faster fire spread and greater fire intensities.  You’ll need a larger Safety Zone if that fire is coming towards you.

The current equation for safety zone size in the IRPG (page 8) is:

4 x Flame Height = Safe Separation Distance

To make estimations of flame height though, you either have to use past fire behavior observations or use your experience to guess what the fire may do in the future.  After a decade of research, Bret Butler, at the Missoula Technology and Development Center, suggests removing the uncertainty and guesswork that comes with estimating flame height by taking the general rule of thumb: Flame Height = 2 x Vegetation Height

…and substituting that Flame Height equation into the original IRPG equation, to give:

4 x 2 x Vegetation Height = Safe Separation Distance, which simplified is:

8 x Vegetation Height = Safe Separation Distance

 

But remember, that’s still for radiant heat only, on flat ground, with no wind. To take into account the convective heat from slope or wind, Butler’s research suggests that a “Slope Wind Factor” is needed in the equation:

8 x Vegetation Height x Slope Wind Factor = Safe Separation Distance

 

But what is the Slope Wind Factor? Current research is indicating that the Slope Wind Factor is between 1 and 10; with Butler arguing it may be closer to between 1 and 5. Butler’s ongoing research is focused on answering that question by gathering sensor data on fires, running computer simulations, and refining the models…Stay tuned.

In the meantime, utilize the calculations on page 8 of your IRPG to help you determine a bare minimum size for your safety zone with the understanding that slope and wind need to be considered in your decision making.

But remember, a safety zone is only good if you can get there…join us tomorrow for some thoughts on Escape Routes.

The “Take 5@2” safety messages are a cooperative project of 6 Minutes for Safety, the Wildland Fire Safety Training Annual Refresher (WFSTAR), NIFC External Affairs, the NWCG Leadership Committee, the NWCG Risk Management Committee, and the Wildland Fire Lessons Learned Center.

Page Last Modified / Reviewed:

Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee.


Follow NWCG on Twitter and Facebook

NWCG Latest Announcements

Updated NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

Date: May 10, 2024
Contact: IFUASS Qualification and Curriculum Board (IFUASS) 

The 2024 revision of the NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515 is now available. PMS 515 standardizes the processes and procesures for interagency use of Unmanned Aircraft Systems (UAS), including pilot inspections and approvals. This publication is now available as a PDF for easy use offline.

References:

NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

Memorandum 24-003: Removal of Type 1 Command and General Staff (C&G) Incident Position Qualification Pathways

Date: May 10, 2024
Contact: Aitor Bidaburu 

The purpose of this memorandum is to provide NWCG direction for removal of the Type 1 Command and General Staff (C&G) incident position qualification pathways to transition to Complex Incident Management (CIM). Responders may continue to utilize available NWCG pathways to attain Type 1 C&G qualifications until December 31, 2024.

References:

Memorandum 24-003

CIM Story Map

2024 Professional Reading Program

Date: April 26, 2024
Contact: Wildland Fire Leadership Development Program (WFLDP) 

The Wildland Fire Leadership Development Program is announcing the 2024 Professional Reading list! The intent of the Professional Reading Program is to promote the reading and discussion of these books throughout the year. Discussion guides are provided and the corresponding Wildland Fire Leadership Levels have been identified.

The five books chosen for this year are: Young Men and Fire by Norman Maclean, The Wisdom of the Bullfrog by William H. McRaven, The Art of Clear Thinking by Hasard Lee, Emotional Agility by Susan David, and Writing to Persuade by Trish Hall.

References:

Professional Reading Program

Wildland Fire Leadership Levels

NWCG Training Catalog now on Wildland Fire Learning Portal

Date: April 25, 2023
Contact: NWCG Training  

The National Wildfire Coordinating Group (NWCG) has migrated the training catalog from the NWCG website to the Wildland Fire Learning Portal (WFLP) as part of our ongoing efforts to streamline processes and improve efficiency. To facilitate this transition, the training catalog remains available on www.nwcg.gov through April 2024.

Starting May 2024, the training catalog will no longer be accessible on www.nwcg.gov. However, you can still access the complete training catalog by logging in as a guest to the WFLP.

References:

Wildland Fire Learning Portal