Skip to main content

Tank – Collapsible, 3000 GL (11,356.2L)

NFES #
000568
Category
Water Handling
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Separate tanks by NFES number. Inspect for punctures, tears.  Look for damaged couplings, and drain plugs.  Inspect flanges and make sure threads are not damaged.
  2. Ensure ball bearings on fitting are working properly.  Repair or lube if necessary.
  3. Inspect seal around flange.  Replace to 2 ½” female flange if tank return is equipped with fittings other than.
  4. Return to stock if unused.
  5. Refurbish item if tears and holes are repairable with local equipment and expertise.  Contact manufacturer for repairs requiring materials or skills not found at the local cache to determine if it is economically feasible to have manufacturer repair tank.
  6. Dispose of item if unable to refurbish.

Refurbishing Procedures

A. Cleaning

  1. Elevate tank, securing the tank to lifting system with a chain or straps to bear the weight of the tank.
  2. Clean tank, inside and outside, with soapy water and a brush.
  3. Rinse well with clean water from high-pressure washer.
  4. Allow to air dry on both sides.

B. Repair

  1. While tank is suspended, mark any holes or damage needing repair.
  2. Patch any hole or tears.  Small pin hole can be repaired with manufacturer recommended TEAR-AID® Type B or other similar material recommended by the tank manufacturer.  Larger holes should be patched with material recommended by the manufacturer utilizing a vinyl welding process.  For extremely large holes, contact the tank manufacturer for recommended repair or replacement options.
  3. Replace all damaged hose couplings and drain plugs.
  4. Stencil correct NFES # of item on collar of tank if missing or unreadable.

C. Testing for performance

  1. Check all patches to insure they are secure and there are no loose edges.
  2. Suspend tank again to spot holes while looking towards light.

D. Repackaging

  1. Fold or roll tank as tightly as possible, secure with plastic banding or rope to keep from unrolling.
  2. 1 each of NFES  #006030, #006031, #007744 in NFES #008158 carton (48” x 22” x 31”).
  3. 1 each of NFES #000090, #000588, #000589, #000668, #000568 recommended in NFES #000500 carton (22” x 22” x 36”).

 

NWCG Latest Announcements

Incident Position Standards and Next Generation Position Task Book Available for Firing Boss, Single Resource

Date: April 30, 2025
Questions?  Please contact:
Fuels Management Committee

NWCG is excited to announce that the NWCG Incident Position Standards for Firing Boss, Single Resource, PMS 350-105, and the NWCG Position Task Book for Firing Boss, Single Resource (FIRB), PMS 311-105, are now available. 

These resources, part of the Performance Support Package developed through the Incident Performance and Training Modernization (IPTM) effort, support trainees, qualified personnel, and evaluators. 

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

 

References:

NWCG Firing Boss, Single Resource Position Page

NWCG Incident Position Standards for Firing Boss, Single Resource, PMS 350-105

NWCG Position Task Book for Firing Boss, Single Resource (FIRB), PMS 311-105

Incident Position Standards and Next Generation Position Task Book Available for Helicopter Crewmember

Date: April 28, 2025
Questions?  Please contact:
Interagency Helicopter Operations Subcommittee

NWCG is excited to announce that the NWCG Incident Position Standards for Helicopter Crewmember, PMS 350-22, and the NWCG Position Task Book for Helicopter Crewmember (HECM), PMS 311-22, are now available.

These resources, part of the Performance Support Package developed through the Incident Performance and Training Modernization (IPTM) effort, support trainees, qualified personnel, and evaluators.

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

NWCG Incident Position Standards for Helicopter Crewmember, PMS 350-22

NWCG Incident Position Standards for Helicopter Crewmember, PMS 350-22

NWCG Position Task Book for Helicopter Crewmember (HECM), PMS 311-22

Updated NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

Date: April 23, 2025
Questions?  Please contact:
Interagency Fire Unmanned Aircraft Systems Subcommittee

The NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515 standardizes processes and procedures for the interagency use of Unmanned Aircraft Systems (UAS), including pilot inspections and approvals. This updated publication provides the aviation community with standards to ensure UAS are used safely, effectively, and efficiently in support of fire management goals and objectives.

References:

NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

NWCG National Interagency Aviation Committee

ETC Bulletin 25-001: Retrofitted Hot/Cold Beverage Kits - 2025 Field Season

Date: April 16, 2025
Questions?  Please contact:
Equipment Technology Committee

Due to spout failures and the associated risk of burn injuries, manufacturers have retrofitted the Hot/Cold Beverage Kits using a heat-shrinking band to secure the black spout at the insertion site. The updated kits feature a fluorescent label on each full kit assembly for easy identification. Catering units are encouraged to confirm the clear heat-shrinking bands are intact around each spout before filling.

ETC Bulletin 24-001 regarding Hot/Cold Beverage Kits has been archived and replaced by ETC Bulletin 25-001 for the 2025 season.

References:

NWCG Alerts

ETC-EB-25-001 Retrofitted Hot/Cold Beverage Kits