Skip to main content

Hose – Synthetic, Lined, 1” NPSH X 100’

NFES #
001238
Category
Water Handling
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Segregate by NFES number.
  2. Visually inspect for burns, cuts, damaged fittings.
  3. Recycle brass fittings from disposed hose.
  4. Inspect gasket for cracks, if any replace.
  5. Return to stock if hose is banded and in unused condition.
  6. Refurbish if item passes initial inspection.
  7. Dispose of hose if it fails initial inspection or fails Testing for Performance.  Good couplings should be salvaged from any hose not repairable.

Refurbishing Procedures

A. Testing for Performance

  1. Replace gasket if necessary.
  2. Connect female end of hose to pump or manifold:
    1. Confirm connection ends are not out of round and there is no damage to threads.
    2. All 1½” hose should be NH threads. All 1” hose should be NPSH threads.
  3. Pressure Test:
    1. Start pump.
    2. Make sure nozzles are open. Let all air escape from hose. Shut nozzles.
    3. Pressurize hose to 300 PSI and hold for 3 minutes.
    4. Walk the length of the hose inspecting for the following which indicate a need for repair or disposal:  burns, cuts, or leaks between hose and couplings, at swivel portion of female coupling, and along the length of the hose.
  4. Female and male couplings:
    1. Inspect for leaks where hose goes into coupling.
    2. Inspect for crooked coupling (easier to see when hose is charged).
  5. Shut down pump and relieve water pressure from system.
  6. Remove hose.
  7. Stretch out good hose to drain.

B. Cleaning

  1. Clean excess dirt from hose.
  2. Run hose through hose washer using clean water or clean water with a mild detergent or clean with high pressure wash.
  3. If detergent is used, rinse with clean water.
  4. Allow hose to drain and dry completely before rolling.

C. Repair

  1. Repaired hose shall result in lengths that are a minimum of 90 percent of original length.
  2. Good couplings shall be salvaged from disposed hose.
  3. Re-coupling procedures.
    1. Remove old expansion ring and coupling from hose.
    2. Remove unserviceable portion of hose, squaring end to be re-coupled.
    3. Utilize expander machine to insert new expander and coupling. Follow specific machine operating instructions.
    4. Refurbished hose shall result in hoses that are 90 to 100 foot in length.
    5. Following re-coupling, hose that has been repaired or re-coupled should be retested at a test pressure of at least 50 percent greater than the service test pressure following Testing for Performance above.

D. Repackaging

  1. Roll in a single roll configuration with male coupling in center of roll.
  2. Secure roll (plastic band, string).
  3. Local cache option for storage.
  4. Roll, secure, and place on pallet.
    • ​NFES #000932, #001238 - Cache option.  Recommended quantity per pallet 1” X 100’ length/pallet.
    • NFES #000933, #001239 - Cache option.  Recommended quantity per pallet 1½” X 100’ length/pallet.
    • NFES #000966, #000967 - Cache option quantity per pallet.

 

NWCG Latest Announcements

NWCG Welcomes the Incident Management Team Association as an Associate Member

Date: May 21, 2025
Questions?  Please contact:
https://www.nwcg.gov/contact-us

The NWCG Executive Board is honored to announce that the Incident Management Teams Association (IMTA) has joined the National Wildfire Coordinating Group as an associate member.

IMTA is a dedicated group of incident management professionals committed to enhancing the profession by promoting standards and fostering collaboration across federal, state, local, Tribal, and private sector partners throughout all phases of incident management.

“Joining NWCG aligns with our mission to elevate incident management professionals nationwide,” said Dr. Randal Collins, President of IMTA. “This is a proud moment for all of us committed to advancing public safety.”

References:

Incident Management Teams Association

National Wildfire Coordinating Group

Updated NWCG Guide for Wildland Fire Modules, PMS 431

Date: May 14, 2025
Questions?  Please contact:
Fire Use Subcommittee

The updated NWCG Guide for Wildland Fire Modules, PMS 431 serves as a supplemental resource for wildland fire module operations, providing information frequently used in the field.

PMS 431 defines the organizational structure, staffing, and qualifications for Type 1 and Type 2 Wildland Fire Modules, outlining their roles in wildland fire suppression, prescribed fire, and resource management. The NWCG Guide for Wildland Fire Modules, PMS 431, should be used in conjunction with the NWCG Standards for Wildland Fire Module Operations, PMS 430.

References:

NWCG Guide for Wildland Fire Modules, PMS 431

NWCG Standards for Wildland Fire Module Operations, PMS 430

Updated NWCG Standards for Wildland Fire Resource Typing, PMS 200 Now Includes Off-Highway Vehicle Typing Standards

Date: May 13, 2025
Questions?  Please contact:
Mobile Fire Equipment Subcommittee 

The NWCG Standards for Wildland Fire Resource Typing, PMS 200 has been updated to include newly developed Off-Highway Vehicle (OHV) typing standards. These standards organize OHV information into logical categories and outline key safety requirements for occupants.

NWCG Standards for Wildland Fire Resource Typing, PMS 200 establishes minimum typing standards for aircraft, crews, and equipment used in national mobilization to wildland fire incidents. Typing designations are assigned based on measurable capability and performance criteria.

References:

NWCG Standards for Wildland Fire Resource Typing, PMS 200

NEW! S-204, Interpersonal and Critical Thinking Skills for Safety Officers Now Available

Date: May 12, 2025
Questions?  Please contact:
Risk Management Committee

The S-204, Interpersonal and Critical Thinking Skills for Safety Officers self-directed online course is now available! Developed through the Incident Performance and Training Modernization (IPTM) effort, this training supports individuals working towards Safety Officer, Field (SOFF) incident qualifications.

S-204, Interpersonal and Critical Thinking Skills for Safety Officers focuses on facilitating hazard mitigation conversations and building trust to influence safety-related decisions. Individuals can self-enroll through the Wildland Fire Learning Portal (WFLP).

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

S-204, Interpersonal and Critical Thinking Skills for Safety Officers 

NWCG Safety Officer, Field (SOFF) Position Page

Wildland Fire Learning Portal