Skip to main content

6.7 Closed Traverse

A closed traverse is a series of connected lines whose lengths and bearings are measured off these lines (or sides), which enclose an area. A closed traverse can be used to show the shape of the perimeter of a fire or burn area. If you were to pace continuously along the sides of a closed traverse, the finishing point would be the same as the starting location.

Note in the following sketch how the traverse is followed clockwise. If the direction was followed counterclockwise at any point, the bearing letters would change to their opposites but the numbers would not, as shown in the first sketch (1) below. The second sketch (2) is a closed traverse. Here, the series of lines completes a distance area, and the starting and ending points are the same.
 

Traverse Examples

Example 1 - Jeff paced the perimeter of the Zavala fire. His pace is 13 paces/chain. The declination for his current location is 14.5°E. The direction, distance, and travel for Jeff is as follows: Jeff begins at point 1 and goes N42°W for 27 paces; from point 2 he goes N75°W for 16-1/2 paces; from point 3 he goes N31°W for 24-1/2 paces; from point 4 he goes N36°E for 29-1/2 paces; from point 5 he goes S65°E for 22 paces; from point 6 he goes S13°E for 52-1/2 paces; from point 7 he goes S21°W for 10-1/4 paces back to the starting point, point 1.

Convert the bearings to magnetic readings. Adjust the magnetic readings to true north readings. Plot the closed traverse in feet using an engineer's tenth ruler and protractor.

Step 1. Convert paces into feet. Jeff's pace is 13 paces per chain. Set up the cancellation table (Section 2.1) and solve for distance in feet.

cancellation table
Repeat this step for each distance.

Step 2. Convert the bearings to magnetic readings. See Section 6.1.

The NW quadrant is between 270° and 360°. 360° - 42° = 318° 
The SE quadrant is between 90° and 180°. 180° - 65° = 115°
The NE quadrant is between 0° and 90° so those values are used as recorded.
The SW quadrant is between 180° and 270°. 180° + 21° = 201°

The resulting magnetic reading are listed in the table below. 

Step 3. Adjust each magnetic reading to a true reading following the guidelines in Section 6.5.

Closed Traverse

Step 4. Choose a scale. 1/10 inch = 10 feet

Step 5. Using a protractor (angles measured in degrees) and an engineer's scale or tenth's ruler, plot the plan view of the traverse horizontal distance (feet) and the bearing (degrees) between points.

image of protractor measuring angles

image of engineer's rule

Step 5a. Set the protractor so the 0°/180°line is up (north) and on a north-south axis.

Step 5b. Put a point in the middle hole. This will be point 1.

Step 5c. Read 318° on the outer scale of the protractor.
Put a dot to mark the point.

index point on protractor


Step 5d. Draw a line from point 1 up to the dot that is 13-7/10 marks (each inch has 10 marks).

ruler with points

Step 5e. The end of this line will be point 2. Put the hole of the protractor on point 2. Follow steps 5b and 5c with each of the values.

When plotting the values that are in the southern quadrants with a semicircle protractor, rotate the protractor so the 0°/180°line is down (facing south) and read the numbers on the inner scale. Continue to complete all the points. The end result should be a closed traverse as shown.

Step 5f. Convert the true readings to bearings. 

P1 to P2 = 360° - 332.5° = N27.5°W
P2 to P3 = 360° - 299.5° = N60.5°W
P3 to P4 = 360° - 343.5° = N16.5°W
P4 to P5 = 0° + 50.5° = N50.5°E
P5 to P6 = 180° - 129.5° = S50.5°E
P6 to P7 = 181.5° - 180° = S1.5°E
P7 to P1 = 215.5° - 180° = S35.5°W

Label the lines of the traverse with the corresponding bearings.

 

NWCG Latest Announcements

Updated! L-280, Followership to Leadership (Instructor-led) Course

Date: October 3, 2024
Questions? Please contact:
Leadership Committee

NWCG is pleased to announce the updated L-280, Followership to Leadership (Instructor-led) course is now available. L-280 is intended for operational personnel at the Firefighter Type 1 level, and for individuals pursuing Leadership Level 2, New Leader. 

This instructor-led course is a primer on leadership and the second formal course in the Wildland Fire Leadership Development Program. It helps emerging leaders build the confidence, skills, and mindset needed to lead effectively in high-risk environments. 

For more information about leadership development and available courses, visit the Leadership Committee Web Portal.

References:

L-280, Followership to Leadership (Instructor-led)

Wildland Fire Leadership Development Program

Wildland Fire Learning Portal

Equipment Advisory 25-01: Pre-2006 Fire Shelter Degradation and Discontinuation of Use

Date: Sept 26, 2025
Questions? Please contact:
Equipment Technology Committee 

The Equipment Technology Committee (ETC) has released Equipment Advisory 25-01: Pre-2006 Fire Shelter Degradation and Discontinuation of Use. This advisory recommends all pre-2006 fire shelters should be removed from service by January 1, 2026.

This advisory recommends firefighters and fire managers to:

  • Inspect fire shelters immediately
  • Replace and destroy any pre-2006 shelters (identified by white or pink insert label)
  • Order replacements as needed

For further details, please refer to the complete advisory. 

References:

Equipment Advisory 25-01: Pre-2006 Fire Shelter Degradation and Discontinuation of Use

NWCG Fire Inspection Flowchart, PMS 411-1

NWCG Alerts

NEW! S-219, Firing Operations (Blended) Now Available

Date: Sept 11, 2025
Questions? Please contact:
Fuels Management Committee 

The S-219, Firing Operations (Blended) course is now available on the Wildland Fire Learning Portal. Developed through the Incident Performance and Training Modernization (IPTM) effort, this training supports individuals working towards Firing Boss, Single Resource (FIRB) incident qualifications.

This blended course combines online and instructor-led training to provide students with the knowledge and skills required to perform the duties of the FIRB, as described in the NWCG Incident Position Standards for Firing Boss, Single Resource, PMS 350-105.

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1, scheduled for January 2026.

References:

S-219, Firing Operations (Blended)

NWCG Firing Boss, Single Resource Position Page

Wildland Fire Learning Portal

NWCG Committees Observe Suicide Prevention Awareness Week: September 7-13, 2025

Date: Sep 5, 2025
Questions? Please contact:
Mental Health Subcommittee

The NWCG Mental Health Subcommittee (MHSC) and Risk Management Committee (RMC) recognize the unique challenges and demands faced by the wildland fire community. The MHSC and RMC know that we are all stronger together and believe in fostering a culture of support, understanding, and resilience.

Suicide Prevention Awareness encourages us to actively connect with and support each other. For more information that could make a difference for yourself or someone else please review the materials and resources provided for the 2025 Suicide Prevention Awareness Week.

References:

2025 Suicide Prevention Awareness Week Materials and Resources